{"id":3036,"date":"2026-09-12T00:24:02","date_gmt":"2026-09-12T00:24:02","guid":{"rendered":"https:\/\/sentrimax.com\/centrifuge-poor-separation\/"},"modified":"2026-09-12T00:24:02","modified_gmt":"2026-09-12T00:24:02","slug":"centrifuge-poor-separation","status":"publish","type":"page","link":"https:\/\/sentrimax.com\/es\/centrifuge-poor-separation\/","title":{"rendered":"Why Is My Centrifuge Not Separating Properly?"},"content":{"rendered":"<p><!-- SX-AIU:START --><\/p>\n<div class=\"sx-content\">\n<nav class=\"sx-crumb\" aria-label=\"Migaja de pan\"><a href=\"\/es\/centrifuge-troubleshooting\/\">Gu\u00eda de soluci\u00f3n de problemas de la centr\u00edfuga<\/a> \u203a <span>Why Is My Centrifuge Not Separating Properly?<\/span><\/nav>\n<p class=\"sx-answer\">Poor separation in a decanter centrifuge is either a process problem or a mechanical problem, and telling them apart saves unnecessary repairs. Process causes include feed rate, polymer dose, solids loading and differential speed, all adjustable at the plant. Mechanical causes include scroll wear, pond depth drift and beach angle wear, which Sentrimax Centrifuges addresses through inspection and repair.<\/p>\n<h2>Rule out process before assuming the machine is worn<\/h2>\n<p>When cake gets wetter, centrate gets cloudier, or polymer consumption creeps up, the instinct<br \/>\nis often to assume something inside the bowl has worn out. Most of the time that is the wrong<br \/>\nfirst assumption. Separation performance on a decanter centrifuge is a balance between several<br \/>\nadjustable process variables, and a shift in any one of them &mdash; feed characteristics<br \/>\nincluded &mdash; can produce exactly the same symptoms as genuine mechanical wear. Working<br \/>\nthrough the process variables first, in order, is faster and cheaper than sending a machine for<br \/>\ninspection that turns out to be running correctly.<\/p>\n<h2>Process causes an operator can adjust directly<\/h2>\n<ul class=\"sx-check\">\n<li>Feed rate exceeding what the bowl length and pond depth can clarify at the current retention<br \/>\ntime<\/li>\n<li>Polymer dose too low for the current solids concentration, or a change in polymer type,<br \/>\nage, or dilution water quality<\/li>\n<li>Solids loading higher than the machine was sized for, whether from an upstream process<br \/>\nchange or a batch variation<\/li>\n<li>Differential speed set too low or too high for the current feed, changing how long solids<br \/>\nstay in the bowl before discharge<\/li>\n<li>Pond depth set incorrectly for the feed characteristics, affecting clarification time versus<br \/>\ncake dryness<\/li>\n<li>Feed temperature changes affecting polymer performance and settling behaviour<\/li>\n<\/ul>\n<p>A useful test: change one variable at a time, in small steps, and give the machine long<br \/>\nenough to stabilize before judging the result. Changing polymer dose and differential speed in<br \/>\nthe same adjustment makes it impossible to tell which one actually fixed &mdash; or worsened<br \/>\n&mdash; the separation.<\/p>\n<h2>Mechanical causes that process adjustments cannot fix<\/h2>\n<p>If separation stays poor after feed rate, polymer, solids loading, differential speed and<br \/>\npond depth have all been checked and adjusted, the cause has likely moved to the machine<br \/>\nitself:<\/p>\n<div class=\"sx-table-wrap\">\n<table class=\"sx-table\">\n<thead>\n<tr>\n<th>S\u00edntoma<\/th>\n<th>Mechanical cause<\/th>\n<th>What it needs<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Cake dryness drops steadily over weeks or months<\/td>\n<td><a href=\"\/es\/centrifuge-scroll-conveyor-wear\/\">Scroll flight or hardfacing wear<\/a><\/td>\n<td>Inspection<br \/>\nand rebuild of the conveyor<\/td>\n<\/tr>\n<tr>\n<td>Separation worsens along with new vibration<\/td>\n<td>Bowl or scroll imbalance affecting<br \/>\npond behaviour<\/td>\n<td>Ver <a href=\"\/es\/decanter-centrifuge-vibration\/\">Las vibraciones causan<\/a> y<br \/>\nrebalancing<\/td>\n<\/tr>\n<tr>\n<td>Centrate quality degrades gradually, cake stays similar<\/td>\n<td>Weir or dam plate wear<br \/>\nchanging effective pond depth<\/td>\n<td>Weir component replacement<\/td>\n<\/tr>\n<tr>\n<td>Cake dryness and torque both drift the same direction<\/td>\n<td>Beach angle or bowl surface<br \/>\nwear<\/td>\n<td>Bowl inspection and machining<\/td>\n<\/tr>\n<tr>\n<td>Sudden separation collapse, not gradual<\/td>\n<td>Bearing wear altering bowl-to-scroll<br \/>\ndifferential, or a mechanical failure<\/td>\n<td>Immediate inspection &mdash; see the warning<br \/>\nbelow<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<h2>How to run a structured process check<\/h2>\n<p>Rather than adjusting everything at once, work through the variables in an order that isolates<br \/>\ncause from effect. Start with feed rate and solids loading, since these set the baseline load the<br \/>\nmachine has to handle before any chemistry or speed adjustment can compensate. Confirm feed rate<br \/>\nagainst the machine&#8217;s rated capacity and check whether an upstream process change &mdash; a new<br \/>\nbatch, a different waste stream, a seasonal variation in solids concentration &mdash; has pushed<br \/>\nloading above what the current settings were tuned for. Next check polymer: dose rate first, then<br \/>\nwhether the polymer type, age, or make-down water quality has changed, since aged or improperly<br \/>\nmixed polymer performs poorly even at the correct dose. Only after feed and polymer are confirmed<br \/>\ncorrect should differential speed and pond depth be adjusted, since changing them while the feed<br \/>\nside is still unstable makes it hard to tell what actually caused any improvement or decline.<\/p>\n<p>Document each change and the resulting cake dryness or centrate quality before making the next<br \/>\none. A separation problem that takes a week of testing to characterize properly is still faster<br \/>\nand cheaper than an unnecessary shop visit, and the documentation is useful evidence if the<br \/>\nproblem does turn out to be mechanical.<\/p>\n<h2>Industry-specific separation patterns worth knowing<\/h2>\n<p>Feed variability differs meaningfully by application. Municipal water and wastewater<br \/>\noperations dewatering biosolids often see batch-to-batch solids concentration swings that look<br \/>\nlike a mechanical problem but resolve with a polymer dose adjustment. Energy and utilities<br \/>\napplications &mdash; drilling mud treatment, produced water clarification, solids control &mdash;<br \/>\ntend to run more continuously with more consistent feed, so a separation shift on these<br \/>\nsystems is somewhat more likely to indicate genuine mechanical wear once obvious process<br \/>\nvariables have been ruled out. Food and beverage separation, including dairy and brewery waste<br \/>\nmanagement, typically runs at tighter separation tolerances, so a small mechanical change gets<br \/>\nnoticed as a performance complaint sooner than it would on a less tolerance-sensitive<br \/>\napplication.<\/p>\n<h2>What to track before and after any process change<\/h2>\n<p>A separation complaint is much easier to resolve when there is a clear before-and-after record<br \/>\nrather than a general impression that things have gotten worse. At minimum, log cake dryness or<br \/>\npercent solids, centrate turbidity or suspended solids, polymer dose and type, feed rate, and<br \/>\ndifferential speed at the time the complaint started and again after each adjustment. This<br \/>\nmatters as much for ruling mechanical causes in as it does for ruling them out: an inspection<br \/>\nreport showing scroll wear is far more actionable alongside a performance trend showing exactly<br \/>\nwhen and how quickly cake dryness declined, since that trend line often correlates with how far<br \/>\nthe wear has progressed.<\/p>\n<h2>Why increasing polymer dose can hide a mechanical problem<\/h2>\n<p>It is common, and understandable, to respond to slipping separation by increasing polymer<br \/>\ndose until cake dryness comes back to an acceptable level. That works, for a while, against<br \/>\nprocess causes. It does not work indefinitely against mechanical wear, because a worn scroll or<br \/>\na drifted weir keeps degrading conveying and clarification regardless of how well the solids are<br \/>\nflocculated. If polymer consumption has been climbing for months just to hold the same cake<br \/>\ndryness, that trend line itself is diagnostic: it usually means the machine&#8217;s mechanical<br \/>\ncondition, not the chemistry, has moved.<\/p>\n<h2>How Sentrimax evaluates a separation complaint<\/h2>\n<ol class=\"sx-steps\">\n<li><strong>Inspecci\u00f3n y presupuesto.<\/strong> The unit is disassembled and put through a 75-point<br \/>\ninspection, measuring scroll flight profile, pond and beach geometry, and weir condition against<br \/>\nOEM tolerances.<\/li>\n<li><strong>Reparar.<\/strong> Worn flights, tiles, or hardfacing are rebuilt to meet or exceed OEM<br \/>\nspecification, and any bowl or weir wear is machined back to tolerance.<\/li>\n<li><strong>Test run.<\/strong> The rebuilt unit runs a performance test before shipping, confirming<br \/>\nseparation behaviour against the machine&#8217;s original design specification.<\/li>\n<\/ol>\n<div class=\"sx-warn\">\n<h3>Cu\u00e1ndo detener la m\u00e1quina<\/h3>\n<p>Stop and inspect rather than continuing to run through it if separation collapses suddenly<br \/>\nrather than drifting gradually, if it is paired with new vibration or a hot <a href=\"\/es\/centrifuge-bearing-failure\/\">bearing<\/a>, or if cake or centrate quality changes<br \/>\ndramatically within a single shift with no process change to explain it. A sudden collapse<br \/>\npoints to a mechanical failure in progress rather than a process variable that needs tuning, and<br \/>\nrunning through it risks converting a repairable wear issue into a rotating assembly<br \/>\nfailure.<\/p>\n<\/div>\n<h2>What the beach and pond geometry actually do<\/h2>\n<p>The beach is the sloped, dry section of the bowl above the pond where conveyed solids drain<br \/>\nbefore discharge, and its angle and condition directly affect how much liquid drains back before<br \/>\nthe cake exits. Pond depth, set by the position of the weir or dam plates, controls how much of<br \/>\nthe bowl length is used for clarification versus drying. Understanding this relationship helps<br \/>\nexplain a separation trade-off that catches some operators out: increasing pond depth to improve<br \/>\ncentrate clarity reduces the beach length available for drying, so cake dryness and centrate<br \/>\nclarity often move in opposite directions when pond depth is adjusted. A separation complaint<br \/>\nframed only as &#8220;the cake is wet&#8221; without checking what happened to centrate quality at the same<br \/>\ntime can lead to chasing the wrong variable.<\/p>\n<h2>Common mistakes when diagnosing separation problems<\/h2>\n<p>The most frequent mistake is adjusting polymer dose upward repeatedly as a first response to<br \/>\nany separation drift, without checking whether feed rate or solids loading changed first. This<br \/>\noften works well enough in the short term to mask a mechanical cause for weeks, by which point<br \/>\nthe underlying wear has progressed further than it would have if caught early. The second<br \/>\nmistake is changing differential speed and polymer dose in the same adjustment, which makes the<br \/>\nresult impossible to interpret. The third is assuming that because separation problems developed<br \/>\ngradually, they must be mechanical &mdash; a slow seasonal drift in feed characteristics can look<br \/>\nexactly like gradual wear unless it is checked against a process log covering the same<br \/>\nperiod.<\/p>\n<h2>What field service and remote review can offer<\/h2>\n<p>Working through the process checklist above does not require a technician on site. Sentrimax&#8217;s<br \/>\nremote services can review operating parameters, trend data, and photos to help identify which<br \/>\nvariable is most likely responsible, often before deciding whether a field visit or a facility<br \/>\ninspection is warranted. A field service technician becomes useful once process checks are<br \/>\nexhausted and a physical inspection of the feed zone, weir, or scroll condition is needed to<br \/>\nconfirm a mechanical cause, though correcting most mechanical causes &mdash; a scroll rebuild, a<br \/>\nweir replacement, bowl machining &mdash; still requires the assembly to come to a facility.<\/p>\n<h2>Getting help narrowing it down<\/h2>\n<p>The <a href=\"\/es\/centrifuge-troubleshooting\/\">Centro de soluci\u00f3n de problemas de centr\u00edfugas<\/a> covers the other<br \/>\nsymptoms &mdash; vibration, bearing wear, scroll wear &mdash; that separation problems are most<br \/>\noften confused with or accompanied by. If process adjustments have not resolved a separation<br \/>\ncomplaint, Sentrimax can review operating data and photos to help decide what to check next.<\/p>\n<section class=\"sx-faq\">\n<h2>Preguntas frecuentes<\/h2>\n<details>\n<summary>How do I know if poor separation is a process issue or a mechanical issue?<\/summary>\n<div class=\"sx-faq-a\">\n<p>Work through feed rate, polymer dose, solids loading, differential speed and pond depth first, adjusting one at a time. If separation improves, it was process. If it stays poor after all five have been checked and adjusted, the cause is very likely mechanical wear inside the bowl or conveyor.<\/p>\n<\/div>\n<\/details>\n<details>\n<summary>Can increasing polymer dose mask a mechanical problem?<\/summary>\n<div class=\"sx-faq-a\">\n<p>Yes, temporarily. Higher polymer dose can compensate for genuine process shifts, but it cannot indefinitely offset mechanical wear such as a worn scroll or drifted weir. A steadily climbing polymer consumption trend, even with stable cake dryness, is itself a sign the machine&#039;s mechanical condition has changed.<\/p>\n<\/div>\n<\/details>\n<details>\n<summary>Does differential speed affect cake dryness or just throughput?<\/summary>\n<div class=\"sx-faq-a\">\n<p>Both. Differential speed controls how quickly solids move along the scroll and out of the pond. Too fast reduces retention time and leaves cake wetter; too slow can increase torque and, over time, accelerate scroll wear. It needs to be matched to feed characteristics, not set once and left alone.<\/p>\n<\/div>\n<\/details>\n<details>\n<summary>What does a worn scroll actually do to separation performance?<\/summary>\n<div class=\"sx-faq-a\">\n<p>A worn flight or degraded hardfacing conveys solids less efficiently along the beach, increasing the time solids sit wet before discharge and reducing effective cake dryness. It also tends to increase torque, so scroll wear and torque complaints often show up together \u2014 see the scroll and conveyor wear page for detail.<\/p>\n<\/div>\n<\/details>\n<details>\n<summary>Should I keep adjusting the process if separation does not improve?<\/summary>\n<div class=\"sx-faq-a\">\n<p>Give each adjustment a fair trial period, but if you have worked through feed rate, polymer, solids loading, differential speed and pond depth without improvement, stop tuning and get the machine inspected. Continued tuning against a mechanical cause wastes chemical cost without addressing the actual problem.<\/p>\n<\/div>\n<\/details>\n<\/section>\n<section class=\"sx-cta\">\n<h2>Hable con un especialista en centr\u00edfugas.<\/h2>\n<p>Env\u00edenos los detalles de la m\u00e1quina y le enviaremos un informe de inspecci\u00f3n y un presupuesto.<\/p>\n<p><a class=\"sx-btn\" href=\"\/es\/contact\/\">Get a separation performance review<\/a><\/section>\n<\/div>\n<p><!-- SX-AIU:END --><\/p>","protected":false},"excerpt":{"rendered":"<p>Poor separation in a decanter centrifuge is either a process problem or a mechanical problem, and telling them apart saves unnecessary repairs. Process causes include feed rate, polymer dose, solids loading and differential speed, all adjustable at the plant. Mechanical causes include scroll wear, pond depth drift and beach angle wear, which Sentrimax Centrifuges addresses through inspection and repair.<\/p>","protected":false},"author":10,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_acf_changed":false,"inline_featured_image":false,"footnotes":""},"class_list":["post-3036","page","type-page","status-publish","hentry"],"acf":[],"aioseo_notices":[],"aioseo_head":"\n\t\t<!-- All in One SEO 5.0.1.1 - aioseo.com -->\n\t<meta name=\"description\" content=\"Poor centrifuge separation can be a process problem or a mechanical one. Learn to tell feed, polymer and speed issues apart from scroll and bowl wear.\" \/>\n\t<meta name=\"robots\" content=\"max-image-preview:large\" \/>\n\t<link rel=\"canonical\" href=\"https:\/\/sentrimax.com\/es\/centrifuge-poor-separation\/\" \/>\n\t<meta name=\"generator\" content=\"All in One SEO (AIOSEO) 5.0.1.1\" \/>\n\t\t<meta property=\"og:locale\" content=\"es_ES\" \/>\n\t\t<meta property=\"og:site_name\" content=\"Sentrimax Centrifuges -\" \/>\n\t\t<meta property=\"og:type\" content=\"article\" \/>\n\t\t<meta property=\"og:title\" content=\"Why Is My Centrifuge Not Separating Properly? | Sentrimax\" \/>\n\t\t<meta property=\"og:description\" content=\"Poor centrifuge separation can be a process problem or a mechanical one. Learn to tell feed, polymer and speed issues apart from scroll and bowl wear.\" \/>\n\t\t<meta property=\"og:url\" content=\"https:\/\/sentrimax.com\/es\/centrifuge-poor-separation\/\" \/>\n\t\t<meta property=\"og:image\" content=\"https:\/\/sentrimax.com\/wp-content\/uploads\/2025\/05\/Group-1-1.png\" \/>\n\t\t<meta property=\"og:image:secure_url\" content=\"https:\/\/sentrimax.com\/wp-content\/uploads\/2025\/05\/Group-1-1.png\" \/>\n\t\t<meta property=\"og:image:width\" content=\"384\" \/>\n\t\t<meta property=\"og:image:height\" content=\"128\" \/>\n\t\t<meta property=\"article:published_time\" content=\"2026-09-12T00:24:02+00:00\" \/>\n\t\t<meta property=\"article:modified_time\" content=\"2026-09-12T00:24:02+00:00\" \/>\n\t\t<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n\t\t<meta name=\"twitter:title\" content=\"Why Is My Centrifuge Not Separating Properly? | Sentrimax\" \/>\n\t\t<meta name=\"twitter:description\" content=\"Poor centrifuge separation can be a process problem or a mechanical one. Learn to tell feed, polymer and speed issues apart from scroll and bowl wear.\" \/>\n\t\t<meta name=\"twitter:image\" content=\"https:\/\/sentrimax.com\/wp-content\/uploads\/2025\/05\/Group-1-1.png\" \/>\n\t\t<script type=\"application\/ld+json\" class=\"aioseo-schema\">\n\t\t\t{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/sentrimax.com\\\/es\\\/centrifuge-poor-separation\\\/#breadcrumblist\",\"itemListElement\":[{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/sentrimax.com\\\/es#listItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/sentrimax.com\\\/es\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/sentrimax.com\\\/es\\\/centrifuge-poor-separation\\\/#listItem\",\"name\":\"Why Is My Centrifuge Not Separating Properly?\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/sentrimax.com\\\/es\\\/centrifuge-poor-separation\\\/#listItem\",\"position\":2,\"name\":\"Why Is My Centrifuge Not Separating Properly?\",\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/sentrimax.com\\\/es#listItem\",\"name\":\"Home\"}}]},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/sentrimax.com\\\/es\\\/#organization\",\"name\":\"Sentrimax Centrifuges\",\"url\":\"https:\\\/\\\/sentrimax.com\\\/es\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"url\":\"https:\\\/\\\/sentrimax.com\\\/wp-content\\\/uploads\\\/2025\\\/05\\\/Group-1-1.png\",\"@id\":\"https:\\\/\\\/sentrimax.com\\\/es\\\/centrifuge-poor-separation\\\/#organizationLogo\",\"width\":384,\"height\":128},\"image\":{\"@id\":\"https:\\\/\\\/sentrimax.com\\\/es\\\/centrifuge-poor-separation\\\/#organizationLogo\"}},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/sentrimax.com\\\/es\\\/centrifuge-poor-separation\\\/#webpage\",\"url\":\"https:\\\/\\\/sentrimax.com\\\/es\\\/centrifuge-poor-separation\\\/\",\"name\":\"Why Is My Centrifuge Not Separating Properly? | Sentrimax\",\"description\":\"Poor centrifuge separation can be a process problem or a mechanical one. Learn to tell feed, polymer and speed issues apart from scroll and bowl wear.\",\"inLanguage\":\"es-ES\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/sentrimax.com\\\/es\\\/#website\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/sentrimax.com\\\/es\\\/centrifuge-poor-separation\\\/#breadcrumblist\"},\"datePublished\":\"2026-09-12T00:24:02+00:00\",\"dateModified\":\"2026-09-12T00:24:02+00:00\"},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/sentrimax.com\\\/es\\\/#website\",\"url\":\"https:\\\/\\\/sentrimax.com\\\/es\\\/\",\"name\":\"Sentrimax Centrifuges\",\"inLanguage\":\"es-ES\",\"publisher\":{\"@id\":\"https:\\\/\\\/sentrimax.com\\\/es\\\/#organization\"}}]}\n\t\t<\/script>\n\t\t<!-- All in One SEO -->\n\n","aioseo_head_json":{"title":"Why Is My Centrifuge Not Separating Properly? | Sentrimax","description":"Poor centrifuge separation can be a process problem or a mechanical one. Learn to tell feed, polymer and speed issues apart from scroll and bowl wear.","canonical_url":"https:\/\/sentrimax.com\/es\/centrifuge-poor-separation\/","robots":"max-image-preview:large","keywords":"","webmasterTools":{"miscellaneous":""},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"BreadcrumbList","@id":"https:\/\/sentrimax.com\/es\/centrifuge-poor-separation\/#breadcrumblist","itemListElement":[{"@type":"ListItem","@id":"https:\/\/sentrimax.com\/es#listItem","position":1,"name":"Home","item":"https:\/\/sentrimax.com\/es","nextItem":{"@type":"ListItem","@id":"https:\/\/sentrimax.com\/es\/centrifuge-poor-separation\/#listItem","name":"Why Is My Centrifuge Not Separating Properly?"}},{"@type":"ListItem","@id":"https:\/\/sentrimax.com\/es\/centrifuge-poor-separation\/#listItem","position":2,"name":"Why Is My Centrifuge Not Separating Properly?","previousItem":{"@type":"ListItem","@id":"https:\/\/sentrimax.com\/es#listItem","name":"Home"}}]},{"@type":"Organization","@id":"https:\/\/sentrimax.com\/es\/#organization","name":"Sentrimax Centrifuges","url":"https:\/\/sentrimax.com\/es\/","logo":{"@type":"ImageObject","url":"https:\/\/sentrimax.com\/wp-content\/uploads\/2025\/05\/Group-1-1.png","@id":"https:\/\/sentrimax.com\/es\/centrifuge-poor-separation\/#organizationLogo","width":384,"height":128},"image":{"@id":"https:\/\/sentrimax.com\/es\/centrifuge-poor-separation\/#organizationLogo"}},{"@type":"WebPage","@id":"https:\/\/sentrimax.com\/es\/centrifuge-poor-separation\/#webpage","url":"https:\/\/sentrimax.com\/es\/centrifuge-poor-separation\/","name":"Why Is My Centrifuge Not Separating Properly? | Sentrimax","description":"Poor centrifuge separation can be a process problem or a mechanical one. Learn to tell feed, polymer and speed issues apart from scroll and bowl wear.","inLanguage":"es-ES","isPartOf":{"@id":"https:\/\/sentrimax.com\/es\/#website"},"breadcrumb":{"@id":"https:\/\/sentrimax.com\/es\/centrifuge-poor-separation\/#breadcrumblist"},"datePublished":"2026-09-12T00:24:02+00:00","dateModified":"2026-09-12T00:24:02+00:00"},{"@type":"WebSite","@id":"https:\/\/sentrimax.com\/es\/#website","url":"https:\/\/sentrimax.com\/es\/","name":"Sentrimax Centrifuges","inLanguage":"es-ES","publisher":{"@id":"https:\/\/sentrimax.com\/es\/#organization"}}]},"og:locale":"es_ES","og:site_name":"Sentrimax Centrifuges -","og:type":"article","og:title":"Why Is My Centrifuge Not Separating Properly? | Sentrimax","og:description":"Poor centrifuge separation can be a process problem or a mechanical one. Learn to tell feed, polymer and speed issues apart from scroll and bowl wear.","og:url":"https:\/\/sentrimax.com\/es\/centrifuge-poor-separation\/","og:image":"https:\/\/sentrimax.com\/wp-content\/uploads\/2025\/05\/Group-1-1.png","og:image:secure_url":"https:\/\/sentrimax.com\/wp-content\/uploads\/2025\/05\/Group-1-1.png","og:image:width":384,"og:image:height":128,"article:published_time":"2026-09-12T00:24:02+00:00","article:modified_time":"2026-09-12T00:24:02+00:00","twitter:card":"summary_large_image","twitter:title":"Why Is My Centrifuge Not Separating Properly? | Sentrimax","twitter:description":"Poor centrifuge separation can be a process problem or a mechanical one. Learn to tell feed, polymer and speed issues apart from scroll and bowl wear.","twitter:image":"https:\/\/sentrimax.com\/wp-content\/uploads\/2025\/05\/Group-1-1.png"},"aioseo_meta_data":{"post_id":"3036","title":"Why Is My Centrifuge Not Separating Properly? | Sentrimax","description":"Poor centrifuge separation can be a process problem or a mechanical one. Learn to tell feed, polymer and speed issues apart from scroll and bowl wear.","keywords":null,"keyphrases":null,"primary_term":null,"canonical_url":null,"og_title":null,"og_description":null,"og_object_type":"default","og_image_type":"default","og_image_custom_url":null,"og_image_custom_fields":null,"og_image_url":null,"og_image_width":null,"og_image_height":null,"og_video":null,"og_custom_url":null,"og_article_section":null,"og_article_tags":null,"twitter_use_og":false,"twitter_card":"default","twitter_image_type":"default","twitter_image_custom_url":null,"twitter_image_custom_fields":null,"twitter_image_url":null,"twitter_title":null,"twitter_description":null,"schema_type":"default","schema_type_options":null,"schema":{"blockGraphs":[],"customGraphs":[],"default":{"data":{"Article":[],"Course":[],"Dataset":[],"FAQPage":[],"Movie":[],"Person":[],"Product":[],"ProductReview":[],"Car":[],"Recipe":[],"Service":[],"SoftwareApplication":[],"WebPage":[]},"graphName":"WebPage","isEnabled":true},"graphs":[]},"pillar_content":false,"robots_default":true,"robots_noindex":false,"robots_noarchive":false,"robots_nosnippet":false,"robots_nofollow":false,"robots_noimageindex":false,"robots_noodp":false,"robots_notranslate":false,"robots_max_snippet":null,"robots_max_videopreview":null,"robots_max_imagepreview":"large","priority":null,"frequency":null,"local_seo":null,"limit_modified_date":false,"ai":null,"breadcrumb_settings":null,"seo_analyzer_scan_date":null,"created":"2026-09-12 00:24:02","updated":"2026-09-12 00:34:05","focus_keyword":null,"additional_keywords":null,"truseo_locale":null},"aioseo_breadcrumb":"<div class=\"aioseo-breadcrumbs\"><span class=\"aioseo-breadcrumb\">\n\t\t\t<a href=\"https:\/\/sentrimax.com\/es\" title=\"Home\">Home<\/a>\n\t\t<\/span><span class=\"aioseo-breadcrumb-separator\">&raquo;<\/span><span class=\"aioseo-breadcrumb\">\n\t\t\tWhy Is My Centrifuge Not Separating Properly?\n\t\t<\/span><\/div>","aioseo_breadcrumb_json":[{"label":"Home","link":"https:\/\/sentrimax.com\/es"},{"label":"Why Is My Centrifuge Not Separating Properly?","link":"https:\/\/sentrimax.com\/es\/centrifuge-poor-separation\/"}],"_links":{"self":[{"href":"https:\/\/sentrimax.com\/es\/wp-json\/wp\/v2\/pages\/3036","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/sentrimax.com\/es\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/sentrimax.com\/es\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/sentrimax.com\/es\/wp-json\/wp\/v2\/users\/10"}],"replies":[{"embeddable":true,"href":"https:\/\/sentrimax.com\/es\/wp-json\/wp\/v2\/comments?post=3036"}],"version-history":[{"count":0,"href":"https:\/\/sentrimax.com\/es\/wp-json\/wp\/v2\/pages\/3036\/revisions"}],"wp:attachment":[{"href":"https:\/\/sentrimax.com\/es\/wp-json\/wp\/v2\/media?parent=3036"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}